Test-products-international 133 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Test-products-international 133. Test Products International 133 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Digital Multimeter

133Digital MultimeterInstruction Manual

Strany 2 - A. INTRODUCTION

102. Step by Step Procedures:a. Measuring DC VoltsCAUTION!Do not attempt to make a voltage measurement if a test lead is plugged in the A or µmA input

Strany 3

102. Step by Step Procedures:a. Measuring DC VoltsCAUTION!Do not attempt to make a voltage measurement if a test lead is plugged in the A or µmA input

Strany 4 - B. SAFETY CONSIDERATIONS

Application NotesDisconnect power from the terminalblock, find the fuse or circuit breaker thatcontrols the block and turn it off.Set up the meter fol

Strany 5

Application NotesDisconnect power from the terminalblock, find the fuse or circuit breaker thatcontrols the block and turn it off.Set up the meter fol

Strany 6 - C. TECHNICAL DATA

1514d. Measuring AC AmpsCAUTION!Do not attempt to make a current measurement with the test leads connected in parallel with the circuit to betested.

Strany 7

1514d. Measuring AC AmpsCAUTION!Do not attempt to make a current measurement with the test leads connected in parallel with the circuit to betested.

Strany 8 - UL 3111-1

1716Application NotesWhen measuring resistance of a motor,make sure the power is disconnected priorto testing.Set up the meter following steps under“

Strany 9

1716Application NotesWhen measuring resistance of a motor,make sure the power is disconnected priorto testing.Set up the meter following steps under“

Strany 10 - D. MEASUREMENT TECHNIQUES

1918g. Continuity BuzzerWARNING!Do not attempt to make continuity measurements withcircuit energized. Instrument set-up:FUNCTION BLACK RED TEST LEAD

Strany 11

1918g. Continuity BuzzerWARNING!Do not attempt to make continuity measurements withcircuit energized. Instrument set-up:FUNCTION BLACK RED TEST LEAD

Strany 12

32TABLE OF CONTENTSpageA. INTRODUCTION1. Congratulations . . . . . . . . . . . . . . . . . .32. Product Description . . . . . . . . . . . . . .33. EC

Strany 13

21F. MAINTENANCE1. Battery Replacement: The 133 will display BAT whenthe internal 9 Volt battery needs replacement. The battery is replaced as foll

Strany 14

21F. MAINTENANCE1. Battery Replacement: The 133 will display BAT whenthe internal 9 Volt battery needs replacement. The battery is replaced as foll

Strany 15

WARRANTYPlease refer to product warranty card for warranty statement.22G. TROUBLE SHOOTING GUIDEProblem Probable CausesDoes not power up• Dead or defe

Strany 16

WARRANTYPlease refer to product warranty card for warranty statement.22G. TROUBLE SHOOTING GUIDEProblem Probable CausesDoes not power up• Dead or defe

Strany 17

Test Products International, Inc.L133M • 12/1/97 copyright © 1997 Test Products International, Inc.133 SPECIFICATIONS±0.5% Basic DCV Accuracy (also s

Strany 18 - TEST LEAD TEST LEAD

32TABLE OF CONTENTSpageA. INTRODUCTION1. Congratulations . . . . . . . . . . . . . . . . . .32. Product Description . . . . . . . . . . . . . .33. EC

Strany 19

54B. SAFETY CONSIDERATIONSWARNING: Please follow manufacturers test pro-cedures whenever possible. Do not attempt to measure unknown voltages or c

Strany 20 - E. ACCESSORIES*

54B. SAFETY CONSIDERATIONSWARNING: Please follow manufacturers test pro-cedures whenever possible. Do not attempt to measure unknown voltages or c

Strany 21

2. Product ApplicationsPerform the following tests and/or measurements with the TPI 133 and the appropriate function:HVAC/RFUNCTIONDCmV • Thermocouple

Strany 22 - WARRANTY

2. Product ApplicationsPerform the following tests and/or measurements with the TPI 133 and the appropriate function:HVAC/RFUNCTIONDCmV • Thermocouple

Strany 23

8d. ACARange Resolution Accuracy Overload Protection200µA 0.1µA ±1% of reading, Fuse*2mA 0.001mA ±3 digitsF600V, 2A, 31CM20mA 0.01mA 200mA 0.1mA ±1.

Strany 24 - 133 SPECIFICATIONS

8d. ACARange Resolution Accuracy Overload Protection200µA 0.1µA ±1% of reading, Fuse*2mA 0.001mA ±3 digitsF600V, 2A, 31CM20mA 0.01mA 200mA 0.1mA ±1.

Komentáře k této Příručce